Measuring Principle: | Keypad: |
Transit time difference | 18 Key with tactile action |
Pipe Size: | Response Time: |
S Type : 15 mm ~ 100 mm (1/2" ~ 4") | Less than 1 second |
M Type : 50 mm ~ 1000 mm (2" ~ 40") | Flow Velocity: |
L Type : 300 mm ~ 6000 mm (12" ~ 240") | 0.01 ~ +/- 32 m/s |
HS Type : 15 mm ~ 100 mm (1/2" ~ 4") | Resolution: |
HM Type : 50 mm ~ 1000 mm (2" ~ 40") | 0.0001 m/s |
Pipe Material: | Ambient Temperature: |
Cast Iron, Stainless Steel, Ductile Iron |
|
Copper, PVC, Aluminum, Asbestos | Ambient Humidity: |
Fiberglass... Etc | 90% RH or Less |
Liner Material: | Built-in Battery: |
Tar Epoxy, Rubber, Mortar, Polypropylene, | Ni-MH Battery |
Polystyrol, Polystyrene, Polyester, Ebonite, | Operation Time: |
Polyethylene, Teflon... etc | > 10 Hours |
Display: | Charger: |
4 Line LCD with illumination | 90 ~ 260Vac 50/60 Hz, 8-12 Hr charging |
Flowrate | Data Storage: |
5 digit with decimal point | Operation parameters and totalizer |
Totalizer | figures are stored by EEPROM for more |
8 digit, Forward, Reverse & Net values | than 10 years |
Engineer Unit | Data Logger: |
M3, Liter, US Gallon, Imperial Gallon, | Limitless overwriting in 64 columns |
Million Gallon, Cubic Feet, US Barrels, | (Flowrate, totalizer, time, date included) |
Imperial Barrels, Oil Barrel | Output: |
Time Unit | Pulse (Open collector) |
Second, Minute, Hour, Day | Alarm: |
Other | High/Low with buzzer |
Velocity, Date, Time, Signal condition | Power Consumption: |
Accuracy: | Less than 2W |
+/- 1% ~ +/- 2% value of reading (0.5 ~ 30 m/s) | Dimensions: |
+/-0.5% value of reading (Online calibration) | 210 * 90 * 30 mm |
Repeatability: | Weight: |
+/-0.2% value of reading | 0.5 Kg |
| Protection Class: |
| Converter |
| IP65 |
| Sensor |
| IP68 (Submersible) |