| Excitation: | Keyboard: |
| DC pulsed | 3 external keys for programming |
| Display: | and display control |
| 3 lines LCD with illumination | Remote switch instead, no need to open |
| Line 1 | cover |
| 11 digit totalizer for forward flow | Low Flow Cutoff: |
| 11 digit totalizer for reverse flow | 0 to 9.9 % |
| 11 digit totalizer for difference | Data logger Function: |
| Line 2 | 99 times flowrate records for power on/off |
| 5 digit flowrate / velocity / % / mA / HZ | Record Data: |
| Line 3 | Date/Time when Power on/off |
| Parameter / Query / Clr tot / Query LOG | Flow rate when Power on/off |
| Alarm, Guidance | Totalizer when Power on/off |
| Unit | Damping: |
| M3/H, L/H, Kg/H, T/H, L/min, M3/min, GPH | 0 to 99 Seconds |
| GPM, ML/H, ML/m, ML/sec | Density Setting: |
| Measuring Range: | 0.1 to 9.99 g/cm3 |
| Min. 0 to 0.15 m/s | Self Diagnosis: |
| Max. 0 to 15 m/s | The following error message are |
| Accuracy: | displayed if failure occurs |
| +/-0.2% read-out values (Velocity >=0.5 m/s) | - Coil failure |
| +/-0.001 m/s (Velocity < 0.5 m/s) | - Power failure |
| Repeatability: | - Overanged Output |
| +/-0.05% read-out values | - Internal error |
| Current Output: | - Overflow |
| 4-20 mA (Isolated) | - Empty pipe |
| Load | Cable Entry: |
Max. 600  | Standard :M20 / PG11 Option:1/2"NPTF |
| Pulse output: | Protection Class: |
| Open collector | IP 67, Explosion proof, Exd(ib)ibqllBT5 |
| Rating | Ambient Temperature: |
| 3 to 30 Vdc, 20 mA Max. |
|
| Pulse Rate: | Material: |
| 1)Scale pulse (Pusle/M3, Pulse/L, Other) | Aluminum Alloy |
| 2)Frequency: 0-5000 Hz | Power Supply: |
| Pulse Width: | 90-260 Vac, 50/60 Hz |
| 50% of band width | 24Vdc +/-10% (Option) |
| Alarm: | Power Consumption: |
| High/Low with open collector output | 3-17 W (Dependent on sensor size) |
| Rating | Weight: |
| 3 to 30 Vdc, 20 mA Max. | 4.5 Kg |
| Communication: | Mounting: |
| RS 485 (MODBUS Protocol) | Wall mounting |
| HART signal | Bracket on 2" pipe |
| Data Storage: | |
| Operation parameters and totalizer | |
| figures are stored by EEPROM for more | |
| than 10 years |